Capacity: 1000 Liters (Single Phase with Single Compressor)
Bulk Milk cooling Tank and Accessories
Bulk Milk Cooler, FS.1000, Cap: 1000 L with accessories
a. Milk Tank, Cap: 1000L with RL 5 Controller 1Set
b. Single condensing Unit with one compressor (CR 36)
Installation & commissioning included
CUSTOMER-SCIENTIFIC INTERNATIONAL |
|||
DATA SHEET FOR BULK COOLING UNITS FOR CAP:1000L |
|||
Sr. No. |
Description |
(Single Phase) |
|
Vertical Cylindrical-Open Type |
|||
A BULK MILK COOLER TANK |
|||
1 |
Capacity - Rated |
1000 |
|
2 |
Make and model (SS 304/316) |
Serap Industries/First S |
|
3 |
Material used for construction |
AISI 304 (EN 1.4301) |
|
4 |
Shape/Orientation |
Vertical-Cylindrical |
|
5 |
Overall dimensions |
(LxØxH: 2060x1482x1300) |
|
6 |
Weight |
215 |
|
7 |
No. and RPM of agitators |
ONE/30 RPM |
|
8 |
CIP facility ( Manual / Auto ) |
Manual with a provision for cleaning through balance tank and pump ; Auto ( Available as option at extra price ) |
|
9 |
Facility to measure milk volume |
Dipstick with value table(Included) |
|
B REFRIGERATION UNIT |
|||
1 |
Compressor: |
Hermetically sealed |
|
-- Make |
Emerson |
||
--- Type |
Reciprocating |
||
2 |
---- Model |
CR 36 |
|
---- Nos. |
ONE |
||
3 , 4 & 5 |
(a)No. of compressors |
1 No |
|
(b) |
Cooling Capacity of Compressor (kcal/hr) – minimum 1 x 5785=5785 Kcal/hour |
||
6 to 10 |
Condensing Unit : |
Serap |
|
Capacity of the condensers( watt) |
1 x 9670 |
||
11 |
(a)No. of condensors fans |
1 |
|
12 & 13 |
Receiver size & capacity |
6 Litre |
|
14 |
Thermostatic expansion valve, make , size, capacity |
Danfoss,1x5395W,orifice no. 3 |
|
15 |
Overall weight & dimensions of the unit |
910 x 645 x 880 |
|
16 |
Type of refrigerant |
Freon-22( R-22) |
|
C DESIGN PARAMETERS |
|||
1 |
Ambient temp. considered for design |
38 °C |
|
2 |
Maximum cooling time for |
||
All Milking |
3 hrs from 35 °C - 4 °C |
||
Second Milking |
1.5 hrs from 10 °C - 4 °C |
||
3 |
Temperature range considered for |
||
All Milking |
35 °C - 4 °C |
||
Second Milking |
10 °C - 4 °C |
||
E |
ELECTRICALS |
||
1 |
Connected load in Watts & Amperes for |
||
Compressors |
2680/4.9 |
||
Condenser Fans |
180/.82 |
||
BMC Agitator(s) |
70 watt / 0.35A |
||
BMC Milk Pump |
750 Watt |
||
2 |
Maximum surge current drawn by the each compressor |
7.3
|
|
|
|
|