Atomic Absorption Spectrophotometer
 
Salient Features And Benefits:
  • High Energy Double Beam Optics
  • Automated Six lamp turret with independent power supply and alignment for each lamp
  • Microprocessor and Microcontroller based user friendly, Menu driven with printer interface and optional PC attachment through RS232C / USB interface.
  • ü Microsoft Windows ® based software for Data processing, Storage, Retrieval, Interpretation etc.
  • Background correction with D2 lamp source
  • Saving of optimum parameters
  • Auto Burner Height Optimization and maximum ABS adjustment of burner through membrane Keyboard
  • Auto Flame control
  • Auto scan for wavelength conformation
  • Integral Microcontroller based auto gas box with all safety features

Applications:
For analysis of various metallic constituents in
Soil Fertilizer
Micro Nutrients Plants
Pesticides Foods
Water Biological Matter

Metallurgy Plating
Coal Petrochemicals
Glass Cement
Steel Others

Specifications :
Parameter
Spectral
Range 185 to 900 nm
Bandwidth Auto select in 8 steps from 0.1 to 2.5 nm
Photometric
Range 0 to 2 Abs
Light Source Hollow cathode lamp (HCL)
Back Ground Correction Deuterium Lamp (D2)- Optional
Burner Titanium construction, Premix, laminar flow, 100
mm burner for Air – Acetylene (C2H2)
Fuel Acetylene (C2H2)
Oxidant Air/Nitrous Oxide (N2O)
Flow Control Optional: Integral auto gas control system with
LCD display and panel flow meters, Automatic
flame change over
Safety Features Full safety interlock including pressure sensors,
power failure, Protection, auto ignition, flame
failure detection & burner recognition
Nebulizer Pneumatic, with 90% platinum and 10% iridium
alloy capillary
Sample feed rate 3 to 8 ml/min (adjustable)

Data Processing

Microprocessor Mode 1. Absorbance, 2. Emission, 3. Quantitative
Curve fit (quadratic, least squares), 4.
Concentration of standard and samples graph
on LCD

PC Mode Operating software, Windows XP
1. Absorbance, 2. Concentration (standard
addition and calibration), 3. Curve fit (Quadratic
and Least Squares), 4. Energy Profile, 5.
Emission
Monochromator Czerney Turner 1/3 m with 1800 lines/mm
holographic diffraction grating and hard coated optics with full temperature compensation.
Reciprocal, linear, dispersion is 1.5 to 2.0 nm/mm
Detector Wide range Photo Multiplier Tube (PMT)
System Upgradation Instrument can be upgraded to hydride and cold vapor Generator